GreCon GA 6000

GreCon GA 6000

Laboratory formaldehyde analysis even in case of low emissions

The precise and reliable analysis of the formaldehyde emission from wood based panels - in compliance with the standard EN ISO 12460-3 - is possible with the gas analysis unit GreCon GA 6000. The GA 6000 is characterised by its compact design, the low energy consumption and the intuitive and safe operation via a large colour touch screen.

Benefits at a glance

  • Analysis of the formaldehyde emission in only few hours
  • Accepted by CARB
  • No use of the health-damaging toluol
  • Reliable results also in case of very low emitting samples
  • Intuitive operation via a 10“ color touch screen
  • No waiting times thanks to the programmable heating of the measuring chambers
  • Silent in operation
  • Data export (e.g. history) by USB interface
  • Flexible valve configuration
  • An upgrade of GA 5000 to GA 6000 is generally possible

Design of the system

The two measuring chambers made of polished stainless steel are controlled separately and can be used independently. An airflow of 15.85 gal/hr [60 l/h] with a temperature of 140 °F [60 °C] channels the formaldehyde emitted from the test specimen out of the measuring chamber into gas wash bottles. Before introducing the air into the measuring chambers, it is cleaned with silica gel and filtered to achieve a clean air flow.

According to standard the air flow is fed to four pairs of wash bottles for a period of four hours, i.e. formaldehyde containing air is blown through each pair of wash bottles for one hour. After the forth hour, the air flow is stopped automatically. The sequence to open and close the valves is regulated by the PLC. As measuring temperature and valve configuration can be adapted, a flexible reaction on future changes of the standard is possible. The lines of the test air as well as the valve blocks are heated to avoid any condensation and resulting measuring errors. An automatic leak test issues a warning if a leakage occurs.

The relevant test parameters - as required in EN ISO 12460-3 - can be exported via a USB interface. Furthermore, the sample identification as well as date and time of the test are saved in the history.

Measuring method

The test specimen is introduced with sealed edges into a tempered measuring chamber through which a controlled flow of cleaned and heated air flows. The formaldehyde emitted from the test specimen is transported into wash bottles together with the air flow and absorbed in the distilled water. This part of the test takes four hours in compliance with the standard.

Finally, the formaldehyde concentration in the water of the wash bottles is spectrophotometrically determined by means of the acetylacetone method with [412 nm]. It is possible to analyse two test specimens at the same time but independently from each other in the two chambers of the GA 6000.

SOFTWARE FUNCTIONS AND VISUALIZATION

The software of the GA 6000 is implemented on a PLC with integrated touch panel. Access to the user interface is possible via this touch panel.

The system is operated by the user interface. Here, the user may e.g. switch on the heating, start a test or - if stored - select a special valve configuration. Furthermore, the status of the system is displayed, e.g. the current values of the test parameters temperature, the air flow and the test progress. If required according to EN ISO 12460-3, the parameters of temperature, air flow and pressure are saved as average values for each test hour and each test. Date and time are added automatically. Moreover, the user may enter an individual identification for each test, e.g. a production number. The details of the last ten tests can be seen in the history and exported via USB interface.

Technical Data

  • Supply voltage 230 V ± 10 % / 110 V ± 10 %
    Frequency 50 Hz / 60 Hz
    Mains type Phase/neutral conductor/protective conductor
    Power consumption 500 VA
  • Places of installation (other places of installation on request) Lab
    Ambient temperature 59 to 95 °F [15 to 35 °C]
    Relative humidity non-condensing
    Protection class IP54
  • Type of material Wood-based material, ply wood
    Material/panel size 1.96 in [50 mm]
    Material/panel length 15.74 in [400 mm]
    Material/panel thickness variable
  • Number Double chamber
    Measuring process (see product finder) Optical
    Resolution (diameter of the measured spot) Air flow - display resolution: 0.000001 pixels - Temperature - display resolution: 32.18 °F - Pressure - display resolution: 0.000145 Psi
      Air flow - display resolution: [1 l/h] - Temperature - display resolution: [0.1 °C] - Pressure - display resolution: [1 Pa]
    Test time 4 hours in the chamber + analysis time
    Test parameters according to DIN EN ISO 12460-3 (replaces EN 717-2):  
    Air flow rate 15.8 gal/hr ± 0.79 gal/hr [60 l/h ± 3 l/h]
    Temperature 140 °F [60 °C] ± 32.9 °F [0.5 °C]
    Pressure 159.54 Psi ± 14.5 Psi [1100 Pa ± 100 Pa]
    Test chamber volume respectively 135.25 oz [4,000 ml]
    • USB

Consult our experts

We will be more than happy to help you:

After-sales-service

Fagus GreCon, Inc. offers a network of sales and service partners with internal qualified service staff. Thus, a competent partner is available to you anytime and anywhere.

  • Our experts ensure an optimal and reliable function of your GreCon measuring systems in agreed intervals.

  • The GreCon measuring systems are equipped with the GreCon Remote Support to support the operators. This system makes a safe, easy and quick remote support possible in case of any possible failure, to control the system or to answer questions.

  • Fagus GreCon, Inc. offers a continental network of subsidiaries and sales and service partners with internal qualified service staff. Thus, a competent partner is available to you in case of need within very short time and in short distance.